"""Hybrid inverter support aka platform 205, 745, 753""" from __future__ import annotations import logging from .const import * from .exceptions import RequestFailedException, RequestRejectedException from .inverter import EMSMode, Inverter, OperationMode, SensorKind as Kind from .modbus import ILLEGAL_DATA_ADDRESS from .model import is_2_battery, is_4_mppt, is_745_platform, is_single_phase from .protocol import ProtocolCommand from .sensor import * logger = logging.getLogger(__name__) class ET(Inverter): """Class representing inverter of ET/EH/BT/BH or GE's GEH families AKA platform 205 or 745""" # Modbus registers from offset 0x891c (35100), count 0x7d (125) __all_sensors: tuple[Sensor, ...] = ( Timestamp("timestamp", 35100, "Timestamp"), Voltage("vpv1", 35103, "PV1 Voltage", Kind.PV), Current("ipv1", 35104, "PV1 Current", Kind.PV), Power4("ppv1", 35105, "PV1 Power", Kind.PV), Voltage("vpv2", 35107, "PV2 Voltage", Kind.PV), Current("ipv2", 35108, "PV2 Current", Kind.PV), Power4("ppv2", 35109, "PV2 Power", Kind.PV), Voltage("vpv3", 35111, "PV3 Voltage", Kind.PV), Current("ipv3", 35112, "PV3 Current", Kind.PV), Power4("ppv3", 35113, "PV3 Power", Kind.PV), Voltage("vpv4", 35115, "PV4 Voltage", Kind.PV), Current("ipv4", 35116, "PV4 Current", Kind.PV), Power4("ppv4", 35117, "PV4 Power", Kind.PV), # ppv1 + ppv2 + ppv3 + ppv4 Calculated( "ppv", lambda data: max(0, read_bytes4(data, 35105, 0)) + max(0, read_bytes4(data, 35109, 0)) + max(0, read_bytes4(data, 35113, 0)) + max(0, read_bytes4(data, 35117, 0)), "PV Power", "W", Kind.PV, ), ByteH("pv4_mode", 35119, "PV4 Mode code", "", Kind.PV), EnumH("pv4_mode_label", 35119, PV_MODES, "PV4 Mode", Kind.PV), ByteL("pv3_mode", 35119, "PV3 Mode code", "", Kind.PV), EnumL("pv3_mode_label", 35119, PV_MODES, "PV3 Mode", Kind.PV), ByteH("pv2_mode", 35120, "PV2 Mode code", "", Kind.PV), EnumH("pv2_mode_label", 35120, PV_MODES, "PV2 Mode", Kind.PV), ByteL("pv1_mode", 35120, "PV1 Mode code", "", Kind.PV), EnumL("pv1_mode_label", 35120, PV_MODES, "PV1 Mode", Kind.PV), Voltage("vgrid", 35121, "On-grid L1 Voltage", Kind.AC), Current("igrid", 35122, "On-grid L1 Current", Kind.AC), Frequency("fgrid", 35123, "On-grid L1 Frequency", Kind.AC), # 35124 reserved PowerS("pgrid", 35125, "On-grid L1 Power", Kind.AC), Voltage("vgrid2", 35126, "On-grid L2 Voltage", Kind.AC), Current("igrid2", 35127, "On-grid L2 Current", Kind.AC), Frequency("fgrid2", 35128, "On-grid L2 Frequency", Kind.AC), # 35129 reserved PowerS("pgrid2", 35130, "On-grid L2 Power", Kind.AC), Voltage("vgrid3", 35131, "On-grid L3 Voltage", Kind.AC), Current("igrid3", 35132, "On-grid L3 Current", Kind.AC), Frequency("fgrid3", 35133, "On-grid L3 Frequency", Kind.AC), # 35134 reserved PowerS("pgrid3", 35135, "On-grid L3 Power", Kind.AC), Integer("grid_mode", 35136, "Grid Mode code", "", Kind.PV), Enum2("grid_mode_label", 35136, GRID_MODES, "Grid Mode", Kind.PV), # 35137 reserved PowerS("total_inverter_power", 35138, "Total Power", Kind.AC), # 35139 reserved PowerS("active_power", 35140, "Active Power", Kind.GRID), Calculated( "grid_in_out", lambda data: read_grid_mode(data, 35140), "On-grid Mode code", "", Kind.GRID, ), EnumCalculated( "grid_in_out_label", lambda data: read_grid_mode(data, 35140), GRID_IN_OUT_MODES, "On-grid Mode", Kind.GRID, ), # 35141 reserved Reactive("reactive_power", 35142, "Reactive Power", Kind.GRID), # 35143 reserved Apparent("apparent_power", 35144, "Apparent Power", Kind.GRID), Voltage("backup_v1", 35145, "Back-up L1 Voltage", Kind.UPS), Current("backup_i1", 35146, "Back-up L1 Current", Kind.UPS), Frequency("backup_f1", 35147, "Back-up L1 Frequency", Kind.UPS), Integer("load_mode1", 35148, "Load Mode L1"), # 35149 reserved PowerS("backup_p1", 35150, "Back-up L1 Power", Kind.UPS), Voltage("backup_v2", 35151, "Back-up L2 Voltage", Kind.UPS), Current("backup_i2", 35152, "Back-up L2 Current", Kind.UPS), Frequency("backup_f2", 35153, "Back-up L2 Frequency", Kind.UPS), Integer("load_mode2", 35154, "Load Mode L2"), # 35155 reserved PowerS("backup_p2", 35156, "Back-up L2 Power", Kind.UPS), Voltage("backup_v3", 35157, "Back-up L3 Voltage", Kind.UPS), Current("backup_i3", 35158, "Back-up L3 Current", Kind.UPS), Frequency("backup_f3", 35159, "Back-up L3 Frequency", Kind.UPS), Integer("load_mode3", 35160, "Load Mode L3"), # 35161 reserved PowerS("backup_p3", 35162, "Back-up L3 Power", Kind.UPS), # 35163 reserved PowerS("load_p1", 35164, "Load L1", Kind.AC), # 35165 reserved PowerS("load_p2", 35166, "Load L2", Kind.AC), # 35167 reserved PowerS("load_p3", 35168, "Load L3", Kind.AC), # 35169 reserved PowerS("backup_ptotal", 35170, "Back-up Load", Kind.UPS), # 35171 reserved PowerS("load_ptotal", 35172, "Load", Kind.AC), Integer("ups_load", 35173, "Ups Load", "%", Kind.UPS), Temp("temperature_air", 35174, "Inverter Temperature (Air)", Kind.AC), Temp("temperature_module", 35175, "Inverter Temperature (Module)"), Temp("temperature", 35176, "Inverter Temperature (Radiator)", Kind.AC), Integer("function_bit", 35177, "Function Bit"), Voltage("bus_voltage", 35178, "Bus Voltage", None), Voltage("nbus_voltage", 35179, "NBus Voltage", None), Voltage("vbattery1", 35180, "Battery Voltage", Kind.BAT), CurrentS("ibattery1", 35181, "Battery Current", Kind.BAT), Power4S("pbattery1", 35182, "Battery Power", Kind.BAT), Integer("battery_mode", 35184, "Battery Mode code", "", Kind.BAT), Enum2("battery_mode_label", 35184, BATTERY_MODES, "Battery Mode", Kind.BAT), Integer("warning_code", 35185, "Warning code"), Integer("safety_country", 35186, "Safety Country code", "", Kind.AC), Enum2( "safety_country_label", 35186, SAFETY_COUNTRIES, "Safety Country", Kind.AC ), Integer("work_mode", 35187, "Work Mode code"), Enum2("work_mode_label", 35187, WORK_MODES_ET, "Work Mode"), Integer("operation_mode", 35188, "Operation Mode code"), Long("error_codes", 35189, "Error Codes"), EnumBitmap4("errors", 35189, ERROR_CODES, "Errors"), Energy4("e_total", 35191, "Total PV Generation", Kind.PV), Energy4("e_day", 35193, "Today's PV Generation", Kind.PV), Energy4("e_total_exp", 35195, "Total Energy (export)", Kind.AC), Long("h_total", 35197, "Hours Total", "h", Kind.PV), Energy("e_day_exp", 35199, "Today Energy (export)", Kind.AC), Energy4("e_total_imp", 35200, "Total Energy (import)", Kind.AC), Energy("e_day_imp", 35202, "Today Energy (import)", Kind.AC), Energy4("e_load_total", 35203, "Total Load", Kind.AC), Energy("e_load_day", 35205, "Today Load", Kind.AC), Energy4("e_bat_charge_total", 35206, "Total Battery Charge", Kind.BAT), Energy("e_bat_charge_day", 35208, "Today Battery Charge", Kind.BAT), Energy4("e_bat_discharge_total", 35209, "Total Battery Discharge", Kind.BAT), Energy("e_bat_discharge_day", 35211, "Today Battery Discharge", Kind.BAT), Long("diagnose_result", 35220, "Diag Status Code"), EnumBitmap4("diagnose_result_label", 35220, DIAG_STATUS_CODES, "Diag Status"), # ppv1 + ppv2 + ppv3 + ppv4 + pbattery1 - active_power Calculated( "house_consumption", lambda data: read_bytes4(data, 35105, 0) + read_bytes4(data, 35109, 0) + read_bytes4(data, 35113, 0) + read_bytes4(data, 35117, 0) + read_bytes4_signed(data, 35182) - read_bytes2_signed(data, 35140), "House Consumption", "W", Kind.AC, ), # Voltage("vbattery2", 47924, "Battery2 Voltage", Kind.BAT), # Enum2("battery2_mode_label", 35184, BATTERY_MODES, "Battery2 Mode", Kind.BAT), ) # Modbus registers from offset 0x9088 (37000) __all_sensors_battery: tuple[Sensor, ...] = ( Integer("battery_bms", 37000, "Battery BMS", "", Kind.BAT), Integer("battery_index", 37001, "Battery Index", "", Kind.BAT), Integer("battery_status", 37002, "Battery Status", "", Kind.BAT), Temp("battery_temperature", 37003, "Battery Temperature", Kind.BAT), Integer("battery_charge_limit", 37004, "Battery Charge Limit", "A", Kind.BAT), Integer( "battery_discharge_limit", 37005, "Battery Discharge Limit", "A", Kind.BAT ), Integer("battery_error_l", 37006, "Battery Error L", "", Kind.BAT), Integer("battery_soc", 37007, "Battery State of Charge", "%", Kind.BAT), Integer("battery_soh", 37008, "Battery State of Health", "%", Kind.BAT), Integer("battery_modules", 37009, "Battery Modules", "", Kind.BAT), Integer("battery_warning_l", 37010, "Battery Warning L", "", Kind.BAT), Integer("battery_protocol", 37011, "Battery Protocol", "", Kind.BAT), Integer("battery_error_h", 37012, "Battery Error H", "", Kind.BAT), EnumBitmap22( "battery_error", 37012, 37006, BMS_ALARM_CODES, "Battery Error", Kind.BAT ), Integer("battery_warning_h", 37013, "Battery Warning H", "", Kind.BAT), EnumBitmap22( "battery_warning", 37013, 37010, BMS_WARNING_CODES, "Battery Warning", Kind.BAT, ), Integer("battery_sw_version", 37014, "Battery Software Version", "", Kind.BAT), Integer("battery_hw_version", 37015, "Battery Hardware Version", "", Kind.BAT), Integer( "battery_max_cell_temp_id", 37016, "Battery Max Cell Temperature ID", "", Kind.BAT, ), Integer( "battery_min_cell_temp_id", 37017, "Battery Min Cell Temperature ID", "", Kind.BAT, ), Integer( "battery_max_cell_voltage_id", 37018, "Battery Max Cell Voltage ID", "", Kind.BAT, ), Integer( "battery_min_cell_voltage_id", 37019, "Battery Min Cell Voltage ID", "", Kind.BAT, ), Temp("battery_max_cell_temp", 37020, "Battery Max Cell Temperature", Kind.BAT), Temp("battery_min_cell_temp", 37021, "Battery Min Cell Temperature", Kind.BAT), CellVoltage( "battery_max_cell_voltage", 37022, "Battery Max Cell Voltage", Kind.BAT ), CellVoltage( "battery_min_cell_voltage", 37023, "Battery Min Cell Voltage", Kind.BAT ), # Energy4("battery_total_charge", 37056, "Total Battery 1 Charge", Kind.BAT), # Energy4("battery_total_discharge", 37058, "Total Battery 1 Discharge", Kind.BAT), # String8("battery_sn", 37060, "Battery S/N", Kind.BAT), ) # Modbus registers from offset 0x9858 (39000) __all_sensors_battery2: tuple[Sensor, ...] = ( Integer("battery2_status", 39000, "Battery 2 Status", "", Kind.BAT), Temp("battery2_temperature", 39001, "Battery 2 Temperature", Kind.BAT), Integer( "battery2_charge_limit", 39002, "Battery 2 Charge Limit", "A", Kind.BAT ), Integer( "battery2_discharge_limit", 39003, "Battery 2 Discharge Limit", "A", Kind.BAT, ), Integer("battery2_error_l", 39004, "Battery 2 rror L", "", Kind.BAT), Integer("battery2_soc", 39005, "Battery 2 State of Charge", "%", Kind.BAT), Integer("battery2_soh", 39006, "Battery 2 State of Health", "%", Kind.BAT), Integer("battery2_modules", 39007, "Battery 2 Modules", "", Kind.BAT), Integer("battery2_warning_l", 39008, "Battery 2 Warning L", "", Kind.BAT), Integer("battery2_protocol", 39009, "Battery 2 Protocol", "", Kind.BAT), Integer("battery2_error_h", 39010, "Battery 2 Error H", "", Kind.BAT), EnumBitmap22( "battery2_error", 39010, 39004, BMS_ALARM_CODES, "Battery 2 Error", Kind.BAT ), Integer("battery2_warning_h", 39011, "Battery 2 Warning H", "", Kind.BAT), EnumBitmap22( "battery2_warning", 39011, 39008, BMS_WARNING_CODES, "Battery 2 Warning", Kind.BAT, ), Integer( "battery2_sw_version", 39012, "Battery 2 Software Version", "", Kind.BAT ), Integer( "battery2_hw_version", 39013, "Battery 2 Hardware Version", "", Kind.BAT ), Integer( "battery2_max_cell_temp_id", 39014, "Battery 2 Max Cell Temperature ID", "", Kind.BAT, ), Integer( "battery2_min_cell_temp_id", 39015, "Battery 2 Min Cell Temperature ID", "", Kind.BAT, ), Integer( "battery2_max_cell_voltage_id", 39016, "Battery 2 Max Cell Voltage ID", "", Kind.BAT, ), Integer( "battery2_min_cell_voltage_id", 39017, "Battery 2 Min Cell Voltage ID", "", Kind.BAT, ), Temp( "battery2_max_cell_temp", 39018, "Battery 2 Max Cell Temperature", Kind.BAT ), Temp( "battery2_min_cell_temp", 39019, "Battery 2 Min Cell Temperature", Kind.BAT ), CellVoltage( "battery2_max_cell_voltage", 39020, "Battery 2 Max Cell Voltage", Kind.BAT ), CellVoltage( "battery2_min_cell_voltage", 39021, "Battery 2 Min Cell Voltage", Kind.BAT ), # Energy4("battery2_total_charge", 39054, "Total Battery 2 Charge", Kind.BAT), # Energy4("battery2_total_discharge", 39056, "Total Battery 2 Discharge", Kind.BAT), # String8("battery2_sn", 39058, "Battery 2 S/N", Kind.BAT), ) # Modbus registers from offset 0x89be (35262) __all_sensors_battery2_extended: tuple[Sensor, ...] = ( Voltage("vbattery2", 35262, "Battery2 Voltage", Kind.BAT), CurrentS("ibattery2", 35263, "Battery2 Current", Kind.BAT), Power4S("pbattery2", 35264, "Battery2 Power", Kind.BAT), Integer("battery2_mode", 35266, "Battery2 Mode code", "", Kind.BAT), Enum2("battery2_mode_label", 35266, BATTERY_MODES, "Battery2 Mode", Kind.BAT), ) # Inverter's meter data # Modbus registers from offset 0x8ca0 (36000) __all_sensors_meter: tuple[Sensor, ...] = ( Integer("commode", 36000, "Commode"), Integer("rssi", 36001, "RSSI"), Integer("manufacture_code", 36002, "Manufacture Code"), Integer( "meter_test_status", 36003, "Meter Test Status" ), # 1: correct,2: reverse,3: incorrect,0: not checked Integer( "meter_comm_status", 36004, "Meter Communication Status" ), # 1 OK, 0 NotOK PowerS("active_power1", 36005, "Active Power L1", Kind.GRID), PowerS("active_power2", 36006, "Active Power L2", Kind.GRID), PowerS("active_power3", 36007, "Active Power L3", Kind.GRID), PowerS("active_power_total", 36008, "Active Power Total", Kind.GRID), Reactive("reactive_power_total", 36009, "Reactive Power Total", Kind.GRID), Decimal( "meter_power_factor1", 36010, 1000, "Meter Power Factor L1", "", Kind.GRID ), Decimal( "meter_power_factor2", 36011, 1000, "Meter Power Factor L2", "", Kind.GRID ), Decimal( "meter_power_factor3", 36012, 1000, "Meter Power Factor L3", "", Kind.GRID ), Decimal("meter_power_factor", 36013, 1000, "Meter Power Factor", "", Kind.GRID), Frequency("meter_freq", 36014, "Meter Frequency", Kind.GRID), Float( "meter_e_total_exp", 36015, 1000, "Meter Total Energy (export)", "kWh", Kind.GRID, ), Float( "meter_e_total_imp", 36017, 1000, "Meter Total Energy (import)", "kWh", Kind.GRID, ), Power4S("meter_active_power1", 36019, "Meter Active Power L1", Kind.GRID), Power4S("meter_active_power2", 36021, "Meter Active Power L2", Kind.GRID), Power4S("meter_active_power3", 36023, "Meter Active Power L3", Kind.GRID), Power4S( "meter_active_power_total", 36025, "Meter Active Power Total", Kind.GRID ), Reactive4("meter_reactive_power1", 36027, "Meter Reactive Power L1", Kind.GRID), Reactive4("meter_reactive_power2", 36029, "Meter Reactive Power L2", Kind.GRID), Reactive4("meter_reactive_power3", 36031, "Meter Reactive Power L3", Kind.GRID), Reactive4( "meter_reactive_power_total", 36033, "Meter Reactive Power Total", Kind.GRID ), Apparent4("meter_apparent_power1", 36035, "Meter Apparent Power L1", Kind.GRID), Apparent4("meter_apparent_power2", 36037, "Meter Apparent Power L2", Kind.GRID), Apparent4("meter_apparent_power3", 36039, "Meter Apparent Power L3", Kind.GRID), Apparent4( "meter_apparent_power_total", 36041, "Meter Apparent Power Total", Kind.GRID ), Integer( "meter_type", 36043, "Meter Type", "", Kind.GRID ), # (0: Single phase, 1: 3P3W, 2: 3P4W, 3: HomeKit) Integer("meter_sw_version", 36044, "Meter Software Version", "", Kind.GRID), # Sensors added in some ARM fw update (or platform 745/753), read when flag _has_meter_extended is on Power4S("meter2_active_power", 36045, "Meter 2 Active Power", Kind.GRID), Float( "meter2_e_total_exp", 36047, 1000, "Meter 2 Total Energy (export)", "kWh", Kind.GRID, ), Float( "meter2_e_total_imp", 36049, 1000, "Meter 2 Total Energy (import)", "kWh", Kind.GRID, ), Integer("meter2_comm_status", 36051, "Meter 2 Communication Status"), Voltage("meter_voltage1", 36052, "Meter L1 Voltage", Kind.GRID), Voltage("meter_voltage2", 36053, "Meter L2 Voltage", Kind.GRID), Voltage("meter_voltage3", 36054, "Meter L3 Voltage", Kind.GRID), Current("meter_current1", 36055, "Meter L1 Current", Kind.GRID), Current("meter_current2", 36056, "Meter L2 Current", Kind.GRID), Current("meter_current3", 36057, "Meter L3 Current", Kind.GRID), Energy8( "meter_e_total_exp1", 36092, "Meter Total Energy (export) L1", Kind.GRID ), Energy8( "meter_e_total_exp2", 36096, "Meter Total Energy (export) L2", Kind.GRID ), Energy8( "meter_e_total_exp3", 36100, "Meter Total Energy (export) L3", Kind.GRID ), Energy8("meter_e_total_exp", 36104, "Meter Total Energy (export)", Kind.GRID), Energy8( "meter_e_total_imp1", 36108, "Meter Total Energy (import) L1", Kind.GRID ), Energy8( "meter_e_total_imp2", 36112, "Meter Total Energy (import) L2", Kind.GRID ), Energy8( "meter_e_total_imp3", 36116, "Meter Total Energy (import) L3", Kind.GRID ), Energy8("meter_e_total_imp", 36120, "Meter Total Energy (import)", Kind.GRID), ) # Inverter's MPPT data # Modbus registers from offset 0x89e5 (35301) __all_sensors_mppt: tuple[Sensor, ...] = ( Power4("ppv_total", 35301, "PV Power Total", Kind.PV), Integer("pv_channel", 35303, "PV Channel", "", Kind.PV), Voltage("vpv5", 35304, "PV5 Voltage", Kind.PV), Current("ipv5", 35305, "PV5 Current", Kind.PV), Voltage("vpv6", 35306, "PV6 Voltage", Kind.PV), Current("ipv6", 35307, "PV6 Current", Kind.PV), Voltage("vpv7", 35308, "PV7 Voltage", Kind.PV), Current("ipv7", 35309, "PV7 Current", Kind.PV), Voltage("vpv8", 35310, "PV8 Voltage", Kind.PV), Current("ipv8", 35311, "PV8 Current", Kind.PV), Voltage("vpv9", 35312, "PV9 Voltage", Kind.PV), Current("ipv9", 35313, "PV9 Current", Kind.PV), Voltage("vpv10", 35314, "PV10 Voltage", Kind.PV), Current("ipv10", 35315, "PV10 Current", Kind.PV), Voltage("vpv11", 35316, "PV11 Voltage", Kind.PV), Current("ipv11", 35317, "PV11 Current", Kind.PV), Voltage("vpv12", 35318, "PV12 Voltage", Kind.PV), Current("ipv12", 35319, "PV12 Current", Kind.PV), Voltage("vpv13", 35320, "PV13 Voltage", Kind.PV), Current("ipv13", 35321, "PV13 Current", Kind.PV), Voltage("vpv14", 35322, "PV14 Voltage", Kind.PV), Current("ipv14", 35323, "PV14 Current", Kind.PV), Voltage("vpv15", 35324, "PV15 Voltage", Kind.PV), Current("ipv15", 35325, "PV15 Current", Kind.PV), Voltage("vpv16", 35326, "PV16 Voltage", Kind.PV), Current("ipv16", 35327, "PV16 Current", Kind.PV), # 35328 Warning Message # 35330 Grid10minAvgVoltR # 35331 Grid10minAvgVoltS # 35332 Grid10minAvgVoltT # 35333 Error Message Extend # 35335 Warning Message Extend Power("pmppt1", 35337, "MPPT1 Power", Kind.PV), Power("pmppt2", 35338, "MPPT2 Power", Kind.PV), Power("pmppt3", 35339, "MPPT3 Power", Kind.PV), Power("pmppt4", 35340, "MPPT4 Power", Kind.PV), Power("pmppt5", 35341, "MPPT5 Power", Kind.PV), Power("pmppt6", 35342, "MPPT6 Power", Kind.PV), Power("pmppt7", 35343, "MPPT7 Power", Kind.PV), Power("pmppt8", 35344, "MPPT8 Power", Kind.PV), Current("imppt1", 35345, "MPPT1 Current", Kind.PV), Current("imppt2", 35346, "MPPT2 Current", Kind.PV), Current("imppt3", 35347, "MPPT3 Current", Kind.PV), Current("imppt4", 35348, "MPPT4 Current", Kind.PV), Current("imppt5", 35349, "MPPT5 Current", Kind.PV), Current("imppt6", 35350, "MPPT6 Current", Kind.PV), Current("imppt7", 35351, "MPPT7 Current", Kind.PV), Current("imppt8", 35352, "MPPT8 Current", Kind.PV), Reactive4("reactive_power1", 35353, "Reactive Power L1", Kind.GRID), Reactive4("reactive_power2", 35355, "Reactive Power L2", Kind.GRID), Reactive4("reactive_power3", 35357, "Reactive Power L3", Kind.GRID), Apparent4("apparent_power1", 35359, "Apparent Power L1", Kind.GRID), Apparent4("apparent_power2", 35361, "Apparent Power L2", Kind.GRID), Apparent4("apparent_power3", 35363, "Apparent Power L3", Kind.GRID), ) # Modbus registers of inverter settings, offsets are modbus register addresses __all_settings: tuple[Sensor, ...] = ( Integer("comm_address", 45127, "Communication Address", ""), Long("modbus_baud_rate", 45132, "Modbus Baud rate", ""), Timestamp("time", 45200, "Inverter time"), Integer("sensitivity_check", 45246, "Sensitivity Check Mode", "", Kind.AC), Integer("cold_start", 45248, "Cold Start", "", Kind.AC), Integer("shadow_scan", 45251, "Shadow Scan", "", Kind.PV), Integer("backup_supply", 45252, "Backup Supply", "", Kind.UPS), Integer("unbalanced_output", 45264, "Unbalanced Output", "", Kind.AC), Integer("pen_relay", 45288, "PE-N Relay", "", Kind.AC), Integer("battery_capacity", 45350, "Battery Capacity", "Ah", Kind.BAT), Integer("battery_modules", 45351, "Battery Modules", "", Kind.BAT), Voltage("battery_charge_voltage", 45352, "Battery Charge Voltage", Kind.BAT), Current("battery_charge_current", 45353, "Battery Charge Current", Kind.BAT), Voltage( "battery_discharge_voltage", 45354, "Battery Discharge Voltage", Kind.BAT ), Current( "battery_discharge_current", 45355, "Battery Discharge Current", Kind.BAT ), Integer( "battery_discharge_depth", 45356, "Battery Discharge Depth", "%", Kind.BAT ), Voltage( "battery_discharge_voltage_offline", 45357, "Battery Discharge Voltage (off-line)", Kind.BAT, ), Integer( "battery_discharge_depth_offline", 45358, "Battery Discharge Depth (off-line)", "%", Kind.BAT, ), Decimal("power_factor", 45482, 100, "Power Factor"), Integer("work_mode", 47000, "Work Mode", "", Kind.AC), Integer("dred", 47010, "DRED/Remote Shutdown", "", Kind.AC), Integer( "meter_target_power_offset", 47120, "Meter Target Power Offset", "W", Kind.AC, ), Integer( "battery_soc_protection", 47500, "Battery SoC Protection", "", Kind.BAT ), Integer("grid_export", 47509, "Grid Export Limit Enabled", "", Kind.GRID), Integer("grid_export_limit", 47510, "Grid Export Limit", "W", Kind.GRID), Integer("ems_mode", 47511, "EMS Mode"), Integer("ems_power_limit", 47512, "EMS Power Limit", "W"), Integer("battery_protocol_code", 47514, "Battery Protocol Code", "", Kind.BAT), EcoModeV1("eco_mode_1", 47515, "Eco Mode Group 1"), ByteH("eco_mode_1_switch", 47518, "Eco Mode Group 1 Switch"), EcoModeV1("eco_mode_2", 47519, "Eco Mode Group 2"), ByteH("eco_mode_2_switch", 47522, "Eco Mode Group 2 Switch"), EcoModeV1("eco_mode_3", 47523, "Eco Mode Group 3"), ByteH("eco_mode_3_switch", 47526, "Eco Mode Group 3 Switch"), EcoModeV1("eco_mode_4", 47527, "Eco Mode Group 4"), ByteH("eco_mode_4_switch", 47530, "Eco Mode Group 4 Switch"), Integer("soc_upper_limit", 47760, "SoC Upper Limit"), # Direct BMS communication for EMS Control Integer("bms_version", 47900, "BMS Version"), Integer("bms_bat_modules", 47901, "BMS Battery Modules"), # Real time read from BMS Voltage( "bms_bat_charge_v_max", 47902, "BMS Battery Charge Voltage (max)", Kind.BMS ), Current( "bms_bat_charge_i_max", 47903, "BMS Battery Charge Current (max)", Kind.BMS ), Voltage( "bms_bat_discharge_v_min", 47904, "BMS min. Battery Discharge Voltage (min)", Kind.BMS, ), Current( "bms_bat_discharge_i_max", 47905, "BMS max. Battery Discharge Current (max)", Kind.BMS, ), Voltage("bms_bat_voltage", 47906, "BMS Battery Voltage", Kind.BMS), Current("bms_bat_current", 47907, "BMS Battery Current", Kind.BMS), # Integer("bms_bat_soc", 47908, "BMS Battery State of Charge", "%", Kind.BMS), Integer("bms_bat_soh", 47909, "BMS Battery State of Health", "%", Kind.BMS), Temp("bms_bat_temperature", 47910, "BMS Battery Temperature", Kind.BMS), Long("bms_bat_warning-code", 47911, "BMS Battery Warning Code"), # Reserved Long("bms_bat_alarm-code", 47913, "BMS Battery Alarm Code"), Integer("bms_status", 47915, "BMS Status"), Integer("bms_comm_loss_disable", 47916, "BMS Communication Loss Disable"), # RW settings of BMS voltage rate Integer("bms_battery_string_rate_v", 47917, "BMS Battery String Rate Voltage"), # Direct BMS communication for EMS Control Integer("bms2_version", 47918, "BMS2 Version"), Integer("bms2_bat_modules", 47919, "BMS2 Battery Modules"), # Real time read from BMS Voltage( "bms2_bat_charge_v_max", 47920, "BMS2 Battery Charge Voltage (max)", Kind.BMS, ), Current( "bms2_bat_charge_i_max", 47921, "BMS2 Battery Charge Current (max)", Kind.BMS, ), Voltage( "bms2_bat_discharge_v_min", 47922, "BMS2 min. Battery Discharge Voltage (min)", Kind.BMS, ), Current( "bms2_bat_discharge_i_max", 47923, "BMS2 max. Battery Discharge Current (max)", Kind.BMS, ), Voltage("bms2_bat_voltage", 47924, "BMS2 Battery Voltage", Kind.BMS), Current("bms2_bat_current", 47925, "BMS2 Battery Current", Kind.BMS), # Integer("bms2_bat_soc", 47926, "BMS2 Battery State of Charge", "%", Kind.BMS), Integer("bms2_bat_soh", 47927, "BMS2 Battery State of Health", "%", Kind.BMS), Temp("bms2_bat_temperature", 47928, "BMS2 Battery Temperature", Kind.BMS), Long("bms2_bat_warning-code", 47929, "BMS2 Battery Warning Code"), # Reserved Long("bms2_bat_alarm-code", 47931, "BMS2 Battery Alarm Code"), Integer("bms2_status", 47933, "BMS2 Status"), Integer("bms2_comm_loss_disable", 47934, "BMS2 Communication Loss Disable"), # RW settings of BMS voltage rate Integer( "bms2_battery_string_rate_v", 47935, "BMS2 Battery String Rate Voltage" ), ) # Settings added in ARM firmware 19 __settings_arm_fw_19: tuple[Sensor, ...] = ( Integer("fast_charging", 47545, "Fast Charging Enabled", "", Kind.BAT), Integer("fast_charging_soc", 47546, "Fast Charging SoC", "%", Kind.BAT), EcoModeV2("eco_mode_1", 47547, "Eco Mode Group 1"), ByteH("eco_mode_1_switch", 47549, "Eco Mode Group 1 Switch"), EcoModeV2("eco_mode_2", 47553, "Eco Mode Group 2"), ByteH("eco_mode_2_switch", 47555, "Eco Mode Group 2 Switch"), EcoModeV2("eco_mode_3", 47559, "Eco Mode Group 3"), ByteH("eco_mode_3_switch", 47561, "Eco Mode Group 3 Switch"), EcoModeV2("eco_mode_4", 47565, "Eco Mode Group 4"), ByteH("eco_mode_4_switch", 47567, "Eco Mode Group 4 Switch"), Integer("load_control_mode", 47595, "Load Control Mode", "", Kind.AC), Integer("load_control_switch", 47596, "Load Control Switch", "", Kind.AC), Integer("load_control_soc", 47597, "Load Control SoC", "", Kind.AC), Integer("hardware_feed_power", 47599, "Hardware Feed Power"), Integer("fast_charging_power", 47603, "Fast Charging Power", "%", Kind.BAT), ) # Settings added in ARM firmware 22 __settings_arm_fw_22: tuple[Sensor, ...] = ( Long("peak_shaving_power_limit", 47542, "Peak Shaving Power Limit"), Integer("peak_shaving_soc", 47544, "Peak Shaving SoC"), # EcoModeV2("eco_modeV2_5", 47571, "Eco Mode Version 2 Power Group 5"), # EcoModeV2("eco_modeV2_6", 47577, "Eco Mode Version 2 Power Group 6"), # EcoModeV2("eco_modeV2_7", 47583, "Eco Mode Version 2 Power Group 7"), PeakShavingMode("peak_shaving_mode", 47589, "Peak Shaving Mode"), Integer("dod_holding", 47602, "DoD Holding", "", Kind.BAT), Integer("backup_mode_enable", 47605, "Backup Mode Switch"), Integer("max_charge_power", 47606, "Max Charge Power"), Integer("smart_charging_enable", 47609, "Smart Charging Mode Switch"), Integer("eco_mode_enable", 47612, "Eco Mode Switch"), ) def __init__( self, host: str, port: int, comm_addr: int = 0, timeout: int = 1, retries: int = 3, ): super().__init__(host, port, comm_addr if comm_addr else 0xF7, timeout, retries) self._READ_DEVICE_VERSION_INFO: ProtocolCommand = self._read_command( 0x88B8, 0x0021 ) self._READ_RUNNING_DATA: ProtocolCommand = self._read_command(0x891C, 0x007D) self._READ_METER_DATA: ProtocolCommand = self._read_command(0x8CA0, 0x2D) self._READ_METER_DATA_EXTENDED: ProtocolCommand = self._read_command( 0x8CA0, 0x3A ) self._READ_METER_DATA_EXTENDED2: ProtocolCommand = self._read_command( 0x8CA0, 0x7D ) self._READ_BATTERY_INFO: ProtocolCommand = self._read_command(0x9088, 0x0018) self._READ_BATTERY2_INFO: ProtocolCommand = self._read_command(0x9858, 0x0016) self._READ_BATTERY2_INFO_EXTENDED = self._read_command(0x89BE, 0x06) self._READ_MPPT_DATA: ProtocolCommand = self._read_command(0x89E5, 0x3D) self._has_eco_mode_v2: bool = True self._has_peak_shaving: bool = True self._has_battery: bool = True self._has_battery2: bool = False self._has_meter_extended: bool = False self._has_meter_extended2: bool = False self._has_mppt: bool = False self._sensors = self.__all_sensors self._sensors_battery = self.__all_sensors_battery self._sensors_battery2 = self.__all_sensors_battery2 self._sensors_battery2_extended = self.__all_sensors_battery2_extended self._sensors_meter = self.__all_sensors_meter self._sensors_mppt = self.__all_sensors_mppt self._settings: dict[str, Sensor] = {s.id_: s for s in self.__all_settings} self._sensors_map: dict[str, Sensor] | None = None @staticmethod def _single_phase_only(s: Sensor) -> bool: """Filter to exclude phase2/3 sensors on single phase inverters""" return not ((s.id_.endswith("2") or s.id_.endswith("3")) and "pv" not in s.id_) @staticmethod def _not_extended_meter(s: Sensor) -> bool: """Filter to exclude extended meter sensors""" return s.offset < 36045 @staticmethod def _not_extended_meter2(s: Sensor) -> bool: """Filter to exclude extended meter sensors""" return s.offset < 36058 async def read_device_info(self): response = await self._read_from_socket(self._READ_DEVICE_VERSION_INFO) response = response.response_data() # Modbus registers from 35000 - 35032 self.modbus_version = read_unsigned_int(response, 0) self.rated_power = read_unsigned_int(response, 2) self.ac_output_type = read_unsigned_int( response, 4 ) # 0: 1-phase, 1: 3-phase (4 wire), 2: 3-phase (3 wire) self.serial_number = self._decode(response[6:22]) # 35003 - 350010 self.model_name = self._decode(response[22:32]) # 35011 - 35015 self.dsp1_version = read_unsigned_int(response, 32) # 35016 self.dsp2_version = read_unsigned_int(response, 34) # 35017 self.dsp_svn_version = read_unsigned_int(response, 36) # 35018 self.arm_version = read_unsigned_int(response, 38) # 35019 self.arm_svn_version = read_unsigned_int(response, 40) # 35020 self.firmware = self._decode(response[42:54]) # 35021 - 35027 self.arm_firmware = self._decode(response[54:66]) # 35027 - 35032 if not is_4_mppt(self) and self.rated_power < 15000: # This inverter does not have 4 MPPTs or PV strings self._sensors = tuple(filter(lambda s: not ("pv4" in s.id_), self._sensors)) self._sensors = tuple(filter(lambda s: not ("pv3" in s.id_), self._sensors)) if is_single_phase(self): # this is single phase inverter, filter out all L2 and L3 sensors self._sensors = tuple(filter(self._single_phase_only, self._sensors)) self._sensors_meter = tuple( filter(self._single_phase_only, self._sensors_meter) ) if is_2_battery(self) or self.rated_power >= 25000: self._has_battery2 = True if is_745_platform(self) or self.rated_power >= 15000: self._has_mppt = True self._has_meter_extended = True self._has_meter_extended2 = True else: self._sensors_meter = tuple( filter(self._not_extended_meter, self._sensors_meter) ) # Check and add EcoModeV2 settings added in (ETU fw 19) try: await self._read_from_socket(self._read_command(47547, 6)) self._settings.update({s.id_: s for s in self.__settings_arm_fw_19}) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.debug( "EcoModeV2 settings not supported, switching to EcoModeV1." ) self._has_eco_mode_v2 = False except RequestFailedException: logger.debug("Cannot read EcoModeV2 settings, switching to EcoModeV1.") self._has_eco_mode_v2 = False # Check and add Peak Shaving settings added in (ETU fw 22) try: await self._read_from_socket(self._read_command(47589, 6)) self._settings.update({s.id_: s for s in self.__settings_arm_fw_22}) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.debug("PeakShaving setting not supported, disabling it.") self._has_peak_shaving = False except RequestFailedException: logger.debug("Cannot read _has_peak_shaving settings, disabling it.") self._has_peak_shaving = False async def read_runtime_data(self) -> dict[str, Any]: response = await self._read_from_socket(self._READ_RUNNING_DATA) data = self._map_response(response, self._sensors) self._has_battery = data.get("battery_mode", 0) != 0 if self._has_battery: try: response = await self._read_from_socket(self._READ_BATTERY_INFO) data.update(self._map_response(response, self._sensors_battery)) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "Battery values not supported, disabling further attempts." ) self._has_battery = False else: raise ex if self._has_battery2: try: response = await self._read_from_socket(self._READ_BATTERY2_INFO) data.update(self._map_response(response, self._sensors_battery2)) response = await self._read_from_socket( self._READ_BATTERY2_INFO_EXTENDED ) data.update( self._map_response(response, self._sensors_battery2_extended) ) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "Battery 2 values not supported, disabling further attempts." ) self._has_battery2 = False else: raise ex if self._has_meter_extended2: try: response = await self._read_from_socket(self._READ_METER_DATA_EXTENDED2) data.update(self._map_response(response, self._sensors_meter)) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "Extended meter 2 values not supported, disabling further attempts." ) self._has_meter_extended2 = False self._sensors_meter = tuple( filter(self._not_extended_meter2, self._sensors_meter) ) # Handle if meter_extended is also missing: try: response = await self._read_from_socket( self._READ_METER_DATA_EXTENDED ) data.update(self._map_response(response, self._sensors_meter)) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "Extended meter values not supported, disabling further attempts." ) self._has_meter_extended = False self._sensors_meter = tuple( filter(self._not_extended_meter, self._sensors_meter) ) response = await self._read_from_socket( self._READ_METER_DATA ) data.update( self._map_response(response, self._sensors_meter) ) else: raise ex else: raise ex elif self._has_meter_extended: try: response = await self._read_from_socket(self._READ_METER_DATA_EXTENDED) data.update(self._map_response(response, self._sensors_meter)) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "Extended meter values not supported, disabling further attempts." ) self._has_meter_extended = False self._sensors_meter = tuple( filter(self._not_extended_meter, self._sensors_meter) ) response = await self._read_from_socket(self._READ_METER_DATA) data.update(self._map_response(response, self._sensors_meter)) else: raise ex else: response = await self._read_from_socket(self._READ_METER_DATA) data.update(self._map_response(response, self._sensors_meter)) if self._has_mppt: try: response = await self._read_from_socket(self._READ_MPPT_DATA) data.update(self._map_response(response, self._sensors_mppt)) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.info( "MPPT values not supported, disabling further attempts." ) self._has_mppt = False else: raise ex return data async def read_sensor(self, sensor_id: str) -> Any: sensor: Sensor = self._get_sensor(sensor_id) if sensor: return await self._read_sensor(sensor) if sensor_id.startswith("modbus"): response = await self._read_from_socket( self._read_command(int(sensor_id[7:]), 1) ) return int.from_bytes(response.read(2), byteorder="big", signed=True) raise ValueError(f'Unknown sensor "{sensor_id}"') async def read_setting(self, setting_id: str) -> Any: setting: Sensor = self._settings.get(setting_id) if setting: return await self._read_sensor(setting) if setting_id.startswith("modbus"): response = await self._read_from_socket( self._read_command(int(setting_id[7:]), 1) ) return int.from_bytes(response.read(2), byteorder="big", signed=True) raise ValueError(f'Unknown setting "{setting_id}"') async def _read_sensor(self, sensor: Sensor) -> Any: try: count = (sensor.size_ + (sensor.size_ % 2)) // 2 response = await self._read_from_socket( self._read_command(sensor.offset, count) ) return sensor.read_value(response) except RequestRejectedException as ex: if ex.message == ILLEGAL_DATA_ADDRESS: logger.debug("Unsupported sensor/setting %s", sensor.id_) self._settings.pop(sensor.id_, None) raise ValueError(f'Unknown sensor/setting "{sensor.id_}"') return None async def write_setting(self, setting_id: str, value: Any): setting = self._settings.get(setting_id) if setting: await self._write_setting(setting, value) else: if setting_id.startswith("modbus"): await self._read_from_socket( self._write_command(int(setting_id[7:]), int(value)) ) else: raise ValueError(f'Unknown setting "{setting_id}"') async def _write_setting(self, setting: Sensor, value: Any): if setting.size_ == 1: # modbus can address/store only 16 bit values, read the other 8 bytes response = await self._read_from_socket( self._read_command(setting.offset, 1) ) raw_value = setting.encode_value(value, response.response_data()[0:2]) else: raw_value = setting.encode_value(value) if len(raw_value) <= 2: value = int.from_bytes(raw_value, byteorder="big", signed=True) await self._read_from_socket(self._write_command(setting.offset, value)) else: await self._read_from_socket( self._write_multi_command(setting.offset, raw_value) ) async def read_settings_data(self) -> dict[str, Any]: data = {} for setting in self.settings(): try: value = await self.read_setting(setting.id_) data[setting.id_] = value except (ValueError, RequestFailedException): logger.exception("Error reading setting %s.", setting.id_) data[setting.id_] = None return data async def get_grid_export_limit(self) -> int: return await self.read_setting("grid_export_limit") async def set_grid_export_limit(self, export_limit: int) -> None: if export_limit >= 0: await self.write_setting("grid_export_limit", export_limit) async def get_operation_modes( self, include_emulated: bool ) -> tuple[OperationMode, ...]: result = list(OperationMode) if not self._has_peak_shaving: result.remove(OperationMode.PEAK_SHAVING) if not is_745_platform(self): result.remove(OperationMode.SELF_USE) if not include_emulated: result.remove(OperationMode.ECO_CHARGE) result.remove(OperationMode.ECO_DISCHARGE) return tuple(result) async def get_operation_mode(self) -> OperationMode | None: mode_id = await self.read_setting("work_mode") try: mode = OperationMode(mode_id) except ValueError: logger.debug("Unknown work_mode value %s", mode_id) return None if OperationMode.ECO != mode: return mode eco_mode = await self.read_setting("eco_mode_1") if eco_mode.is_eco_charge_mode(): return OperationMode.ECO_CHARGE if eco_mode.is_eco_discharge_mode(): return OperationMode.ECO_DISCHARGE return OperationMode.ECO async def set_operation_mode( self, operation_mode: OperationMode, eco_mode_power: int = 100, eco_mode_soc: int = 100, ) -> None: if operation_mode == OperationMode.GENERAL: await self.write_setting("work_mode", 0) await self._set_offline(False) await self._clear_battery_mode_param() elif operation_mode == OperationMode.OFF_GRID: await self.write_setting("work_mode", 1) await self._set_offline(True) await self.write_setting("backup_supply", 1) await self.write_setting("cold_start", 4) await self._clear_battery_mode_param() elif operation_mode == OperationMode.BACKUP: await self.write_setting("work_mode", 2) await self._set_offline(False) await self._clear_battery_mode_param() elif operation_mode == OperationMode.ECO: await self.write_setting("work_mode", 3) await self._set_offline(False) elif operation_mode == OperationMode.PEAK_SHAVING: await self.write_setting("work_mode", 4) await self._set_offline(False) await self._clear_battery_mode_param() elif operation_mode == OperationMode.SELF_USE: await self.write_setting("work_mode", 5) await self._set_offline(False) await self._clear_battery_mode_param() elif operation_mode in (OperationMode.ECO_CHARGE, OperationMode.ECO_DISCHARGE): if eco_mode_power < 0 or eco_mode_power > 100: raise ValueError() if eco_mode_soc < 0 or eco_mode_soc > 100: raise ValueError() eco_mode: EcoMode | Sensor = self._settings.get("eco_mode_1") # Load the current values to try to detect schedule type try: await self._read_sensor(eco_mode) except ValueError: pass eco_mode.set_schedule_type(ScheduleType.ECO_MODE, is_745_platform(self)) if operation_mode == OperationMode.ECO_CHARGE: await self.write_setting( "eco_mode_1", eco_mode.encode_charge(eco_mode_power, eco_mode_soc) ) else: await self.write_setting( "eco_mode_1", eco_mode.encode_discharge(eco_mode_power) ) await self.write_setting("eco_mode_2_switch", 0) await self.write_setting("eco_mode_3_switch", 0) await self.write_setting("eco_mode_4_switch", 0) await self.write_setting("work_mode", 3) await self._set_offline(False) async def get_ems_mode(self) -> EMSMode: mode_id = await self.read_setting("ems_mode") try: return EMSMode(mode_id) except ValueError: logger.debug("Unknown EMS mode %s", mode_id) return None async def set_ems_mode( self, ems_mode: EMSMode, ems_power_limit: int | None = None ) -> None: await self.write_setting("ems_mode", ems_mode.value) if ems_power_limit: await self.write_setting("ems_power_limit", ems_power_limit) async def get_ongrid_battery_dod(self) -> int: return 100 - await self.read_setting("battery_discharge_depth") async def set_ongrid_battery_dod(self, dod: int) -> None: if 0 <= dod <= 100: await self.write_setting("battery_discharge_depth", 100 - dod) def _get_sensor(self, sensor_id: str) -> Sensor | None: if self._sensors_map is None: self._sensors_map = {s.id_: s for s in self.sensors()} return self._sensors_map.get(sensor_id) def sensors(self) -> tuple[Sensor, ...]: result = {s.id_: s for s in self._sensors} result.update({s.id_: s for s in self._sensors_meter}) if self._has_battery: result.update({s.id_: s for s in self._sensors_battery}) if self._has_battery2: result.update({s.id_: s for s in self._sensors_battery2}) result.update({s.id_: s for s in self._sensors_battery2_extended}) if self._has_mppt: result.update({s.id_: s for s in self._sensors_mppt}) return result.values() def settings(self) -> tuple[Sensor, ...]: return tuple(self._settings.values()) async def _clear_battery_mode_param(self) -> None: await self._read_from_socket(self._write_command(0xB9AD, 1)) async def _set_offline(self, mode: bool) -> None: value = bytes.fromhex("00070000") if mode else bytes.fromhex("00010000") await self._read_from_socket(self._write_multi_command(0xB997, value))